A Message from NEF's Chairman
Role and Establishment of NEF
Organization
Activities
How to Get to NEF
Contact Us
Activities

New Energy Award 1997

Director-General of the Agency for Natural Resources and Energy Prize
Application category

Dual Effect Power Generation Using Heat from Waste Incineration
Winner
Sakai City
Kubota
Osaka Gas Co., Ltd.

Features of Equipment, Systems and Facilities
A waste power generator which combines a 4,100 kW gas turbine and 12,400 kW steam turbine, with a total output of 16,500 kW.
From the beginning, it was designed as an integrated power generation system for a refuse incineration plant, and made rational and compact.
The amount of dioxin discharged is considerably below the limit.
The gas turbine has a DSS (Daily Start and Stop) function which enables the power generated in the day and at night to be adjusted to 2:1.
The ratio can be adjusted, in addition to the DSS system, to up to 3.5:1 according to the changes in the waste disposed during the daytime and at night.
Also, it can deal with the changes in daytime and nighttime demands of commercial-use power triggered by power sales.
Gas Turbine and Steam Turbine System
Gas Turbine and Steam Turbine System